APPLICATION NOTES
Title |
Doc # |
Applicable Products |
File Size
\ Type |
| VA, VAR, and Power Factor - Fact or Fiction? |
|
2551, 2553, 2503AH, 257xR, 6000, 6010, 6250 |
50K / PDF |
| 257xR Preheat, Glow, Transition and Strike Timing and Level Measurements using a Tube Load |
|
257xR |
60K / PDF |
| K-Factor Defined |
|
2551, 2553, 2503AH, 257xR |
44K / PDF |
| A Modern Approach to AC Analog Transducer Testing |
|
6000, 6010, 6250 |
72K / PDF |
| Specifying Frequency Response of Amplitude Measurements |
|
ALL |
45k / PDF |
| Power Measurements with the 6250 Phase Angle Voltmeter |
|
6250, 6000-2 |
154k / PDF |
| Recommended Periodic Maintenance Procedures for 2503AH, 257xR |
|
2503AH, 257xR |
60K / PDF |
| Crest Factors and Power Analyzers |
|
2551, 2553, 2503AH |
40K / PDF |
| The Importance, and Difficulties, in Measuring Standby Power and Efficiency
|
|
2503AH, 257xR |
208K / PDF |
| Thermocouple Measuring Instrument Calibration |
|
2000 |
428K / PDF |
|
IEEE-488
The IEEE-488, or GPIB, interface has long been the industry standard for instrumentation communication. Xitron has standardized upon the National Instruments brand of hardware, and has written many LabView example applications that are provided below.
The LabView executable files require installation of the LabView Runtime Engine on the target computer. You may install the specific runtime engine for the application you download, or you may install all of them.
For those customers who program in the LabView language, the source code for many of the
LabView applications is provided as a starting place for your programming project. These files
are LLB's.
1500

1596
2000
| |
 |
2000 Data Sheet (200K PDF) |
| |
 |
2000 User Guide (1.4M) - User Guide |
| |
 |
2000datacollection.zip (88K IEEE LabView 5.1) - This is an engineering app that plots the display of a 2000. Source 99K |
| |
 |
2000RS.zip was written in C for DOS computers. It logs the output of a 2000 display to a file. Note: the RS232 routines were provided by Bri Productions serial port communications software CPORT. All Rights Reserved. |
| |
 |
2000RS.txt is the readme file. |
| |
 |
2000.c is the source code. |
| |
|
There is no upgradeable firmware in this product. |
2500

| |
|
There is no upgradeable firmware in this product. |
2503, 2503H

| |
 |
2503Hdemo.zip (55K, LabView 6.0) - This application demonstrates a multiple parameter IEEE command and reply. Source code is included. |
| |
 |
Methods Guide (900K, PDF) This guide contains details regarding the techniques used in all Xitron Power Analyzers to produce the measurement results. |
| |
 |
2503H Operating and Programming Manual (5MB, PDF) |
| |
|
There is no upgradeable firmware in this product. |
2503AH

2551
2553
257xR Ballast Test System
| |
 |
257xR Data Sheet (200K PDF) |
| |
 |
257xR User's Guide (3.4MB PDF) |
| |
 |
257xR_Config25_lv711.zip Version 2.5, (1M, LabView 7.1.1) UPDATED Sep 28, 2005 - This application allows complete 257xR series instrument setup from a single screen using pull-down menus. It also provides a simple and efficient way to create automatic test sequences, including entering test limits. |
| |
 |
257xR Charts (183K, PDF) - These are the diagrams defining the wiring based upon the chart number. |
| |
 |
1500 Load Card Programming.zip (86K LabView 6.0) - Allows you to reprogram the ID codes and the load and filament values. |
| |
 |
1560/1561 Programmable Load Card (9K, PDF) 2574R ID codes for Configuration, Test Sequence and Limits. (53K, PDF) |
| |
 |
257xR Configuration String Example (1K, TXT). |
| |
 |
1560 Variable Load Card codes vs. resistor values.ZIP (23K, LabView 6.0) |
| |
|
|
| |
|
|
| |
 |
257xR Firmware Upgrade (799k)- Version 5.03 of the main firmware. |
| |
 |
257xR Firmware Upgrade (800k)- Version 5.1.2 of the main firmware. |
| |
 |
257xR Firmware Release Notes (v.5.1.2). (51K PDF) Please read this before upgrading your 257xR with new firmware. |
| |
 |
257xR Firmware Release Notes (v.4.2.3). (51K PDF) Please read this before upgrading your 257xR with new firmware. |
| |
 |
257xR_1500_Upload.zip (66K LabView 6.0) - Allows you to upload new flash firmware into the 2574R, 1500 and the 1596 controllers. |
| |
 |
Restrike Configuration Notes (12K PDF) |
2801
2802
Hydra (model 4200)
For Hydra 4200 Bioimpedance device support, please contact XiTRON technologies at
sales@xitrontech.com
Phone: 858-530-8099
Fax: 858-530-8077
Archived Files:
| |
 |
Hydra Brochure (3.7Meg PDF) |
| |
 |
4200 Manual, (6.5Meg PDF) |
| |
 |
Hydra Utilities, (7.1Meg Zip File)May 2003. Windows 95/98/NT. Here are the disks that are shipped with the Hydra. |
| |
 |
Individual Disks:
SetupEXE.zip (Disk1),1.4Meg, This is a zipped EXE, Release Notes, 1K
Disk2, (1.4M)
Disk3, (1.4M)
Disk4, (1.4M)
Disk5, (1.4M)
Disk6, (79K) |
4000, 4000+(plus) and 4000B Utilities
| |
 |
BIS4000 version 1.0c for 4000 and 4000+ instruments. Written for DOS operating systems. BIS4000100C.ZIP 207K |
| |
 |
BIS4000 version 1.0d for 4000B with firmware C:01 BIS4000100D.ZIP 244K |
6000

6010
6250

| |
 |
6250 Data Sheet (200K PDF) |
| |
 |
6250 User's Guide (4M, PDF) |
| |
 |
6250_demo.zip (68K, ZIP) This application displays 13 of the most popular 6250 PAV measurements plus the voltage waveforms for both inputs on a single screen. |
| |
|
6250 Firmware Upgrade - There is no field upgradeable firmware in this product. |
|
|
|
|